Operation Room Air Treatment Unit

Operation Room Air Treatment Unit

Operation room air treatment unit Unique combination design, mixing section, filter section, surface cooling section, heating section, humidification section, muffler section, fan section and other functional sections are independently manufactured, and then combined according to different usage requirements, from general comfort air-conditioning applications to Clean process air conditioners such as hospital operating rooms and integrated circuit clean rooms with strict requirements can meet the requirements. The height and width of the unit can be flexibly selected to meet the needs of the site conditions for the unit's overall dimensions. Can be shipped to the construction site in parts and then assembled on site.

Operation room air treatment unit

Product Introduction


The fresh air enters the air-conditioning unit and is mixed with the return air from the room in the mixing section. The mixed air passes through the primary-effect filter section to remove dust and debris, and then passes through the intermediate-effect filter section for secondary filtration to remove smaller dust and debris. Then, the temperature is cooled or heated through the surface cold section or heating section to make the air reach the required temperature point, and then humidified through the humidification section to the required humidity requirement of the system to reach the specified air supply state point. The treated air is sent into the room.

After determining the cooling capacity, select the appropriate number of rows of tubes according to the sample. The number of rows is large, the cost is increased, and the wind pressure accompanying the demand is also large. It may cause the demand for the motor to increase. Let the design check determine. This needs to be filled in. Inlet air conditions, the temperature of the chilled water used.

Return air condition: directly select the number of table cooler tube rows on the sample.

Fresh air conditions: Select the number of table cooler tube rows directly on the sample.

Mixed air condition: The theoretical calculation is to determine the point of the inlet air condition after mixing according to the new return air volume, and then compare with the outlet air condition to obtain the specific cooling capacity (under the condition of the temperature difference between the inlet and outlet water). The difference of the return air is estimated.


Hot Tags: operation room air treatment unit, China, manufacturers, customized, quotation, low price, made in China, Operation Room Air Treatment Unit, 10000CFM Modular Air Handling Unit, Air Handling Unit, Ductless Chilled Water Air Handling Unit, 25500cmh Marine AHU HVAC, 35000 M3 h Commercial Heat Recovery Unit

 