1. Function Combined Air Conditioning Unit position of the new return air outlet can be set at the end, top or left and right sides according to the design requirements. If it is inconsistent with this sample, the specific opening position should be provided. A regulating valve can be installed on the new air return port. The actuator has three types of manual, electric and pneumatic, which can be selected by the user.
2. Multi-stage Combined Air Conditioning Unit's air filter section has two kinds of primary and medium-efficiency filtration, equipped with diamond bag type, four-peak bag type, and automatic winding type. The filter material is made of high-quality polyester wheel non-woven fabric, and the filter is quickly assembled and disassembled. Mechanism, gland display and alarm device.
3. Function Combined Air Conditioning Unit It is used for cross-air mixing and exhaust air energy recovery in the dual fan system. Multi-stage Combined Air Conditioning Unit section of the box is equipped with a primary air return valve, and the top is an energy recovery device. It uses the cold (heat) of the exhaust air to indirectly cool (heat) the fresh air. The fresh air passes through a plate energy recovery device to recover the sensible heat of the exhaust air. About 60% of energy. At the same time, the exhaust air and the fresh air are not in direct contact, which is especially suitable for the energy recovery of the DC air-conditioning system that eliminates harmful indoor gases.
| Air Handling Unit(Chilled water type) | |||
| Model No | ZK10-6H | ||
| Quantity | units | 2 | |
| Power supply | 380V/3PH/50HZ | ||
| Air Volume | m3/h | 10200 | |
| Fresh air /return air mixing , 10% fresh air ,90% return air | |||
| Fresh air | m3/h | 1000 | |
| Return air | m3/h | 9200 | |
| Enter/leave air temp | 24/11 C | ||
| Cooling section | Cooling capacity | kW | 65 |
| Cooling coils | rows | 6 | |
| Heating capacity | Electrical heating kw | 10 | |
| Filter section | Pre-filter | G4 | |
| Medium filter | F8 | ||
| Blower section | Air flow | cmh | 10200 |
| External static pressure | Pa | 750 | |
| Fan type | DETON Centrifugal fan without volute | ||
| Motor power | kW | 7.5 | |
| Material structure | Double wall panel with 30mm PU FOAM | ||
| Air Damper manual alumunium in supply , return and fresh air | |||
| Unit using for constant temp,constan humidity and cleaning | |||
| Galvanized sheet, coating on outer layer, bottom frame of channel steel | |||
Function Combined Air Conditioning Unit sections features:
Hot Tags: Function Combined Air Conditioning Unit, China, manufacturers, customized, quotation, low price, made in China, Combined Air Conditioning Unit, Clean Room Air Handling Units 100KW, Medical Air Handler, Air Cooled Cleaning Air Conditioner, Combination Air Handling Unit, Clean Room Air Handling Units