Exchanger Air Energy Saving AHU

Handling large amount of wind, high air quality, energy saving, less space, multi-function, low noise, low power consumption, attractive appearance, easy installation and maintenance features.

Exchanger Air Energy Saving AHU is a device that reduces indoor heat and cooling load by recycling exhaust heat (cold volume). It can not only introduce fresh air outside, but also greatly reduce energy consumption, environmental protection and energy saving. Exchanger Air Energy Saving AHU introduces fresh air from the outside through a number of filtration devices and then exchanges heat between the heat exchange device and the indoor return air, so as to improve (reduce) the fresh air temperature and reduce the indoor energy consumption.


There are three ways of traditional Exchanger Air Energy Saving AHU:

1. The fan directly the (advantages: small investment in equipment. Weakness: the energy waste is serious. High temperature and high humidity air directly added to the indoor outdoor, indoor temperature and humidity air directly discharge outside double waste, has an adverse effect on the air conditioning system overload phenomenon such as condensation, and comfort can not meet the requirements)

2. Paper core full heat exchange new fan (advantage: the use of indoor and outdoor temperature difference play a role in energy saving. Weakness: the energy saving effect is not obvious only drop a three or four degrees, nano heat transfer film to replace, otherwise easy to dust pollution caused by the air pressure is too large to cause indoor and outdoor air breakdown when cross contamination, in thermal efficiency is not high and not dehumidification causing dewing phenomenon etc.

3. the wind cold water waste processing (advantage: with the use of the host system chilled water cooling effect is obvious. There was a dehumidification effect. Weakness: the main system energy consumption to the outdoor air cooling. Winter without air conditioning or excessive season can't deal with fresh air, exhaust to assume the other exhaust system, not only energy consumption of the main system and low temperature and humidity air emitted in vain cause energy waste, only focus on the monitoring of temperature for the humidity is difficult to meet the requirements of temperature humidity balance too dry air-condition disease caused by air)    





Technical specification:


                                           Heat Pump Heat Recovery Air Handling Unit

Model No.


HAX


Nominal cooling capacity

kW

9-216


Nominal heating capacity

kW

9.5-224


Power supply


220V-460V/3PH/50Hz-Hz


Refrigerant


R22/R407c/R410a/R134a


Compressor

Type


Hermetic Scroll

Power

kW

1.7-36


Exhaust air system

Air volume

m3/h

1500-36000

ESP.

Pa

100-550


Motor power

kW

0.55-15


Fresh air system

Air volume

m3/h

1000-20000

ESP.

Pa

80-480


Motor power

kW

0.2-5.5


Heat exchange efficiency


>87%


Noise level

dB(A)

48-68


Dimensions

L*W*H

mm

2000x1500x850

Net weight

kg

380-1700








FAQ:

Q1: Do you test all your goods before delivery?

A1: Yes, we have 100% test before delivery.


Q2: What's the terms of delivery?

A2: EXW, FOB, CFR, CIF.


Q3:How about the quality of your product?

A3: Our products strictly manufatured according to national and international standard. We got ISO quality and CE,CCS,SGS…etc.


Q4:OEM provided?

A4:Yes, OEM and ODM is available. Customized.



Hot Tags: exchanger air energy saving ahu, China, manufacturers, customized, quotation, low price, made in China, 150kw Air Handling Unit, Combined Air Conditioning Unit, Clean Room Air Conditioner, Operation Air Handling Unit, Horizontal Air Handling Unit, 26kw Air Handling Unit

 

Previous: AHU Heat Recovery Fresh Air Ventilation Unit
Next: Heat Pump Heat Recovery Air Handling Unit

 

Open Mobile Site

You Might Also Like